S/N 0503 0033
Testing device | Cambridge 540P |
Sampling mode | 24-bit, 96 kHz |
Interface | |
Testing chain | External loopback (line-out - line-in) |
RMAA Version | 6.2.5 |
20 Hz - 20 kHz filter | ON |
Normalize amplitude | ON |
Level change | -2.9 dB / -2.9 dB |
Mono mode | OFF |
Calibration signal, Hz | 1000 |
Polarity | correct/correct |
Frequency response (from 40 Hz to 15 kHz), dB |
+0.81, -0.78
|
Noise level, dB (A) |
-75.8
|
Dynamic range, dB (A) |
75.7
|
THD, % |
0.0014
|
THD + Noise, dB (A) |
-68.7
|
IMD + Noise, % |
0.133
|
Stereo crosstalk, dB |
-80.3
|
IMD at 10 kHz, % |
0.0084
|
RIAA Frequency Accuracy |
Left
|
Right
|
From 20 Hz to 20 kHz, dB |
-1.65, +0.70
|
-1.61, +0.62
|
From 40 Hz to 15 kHz, dB |
-0.72, +0.70
|
-0.75, +0.62
|
Left
|
Right
|
|
RMS power, dB |
-62.7
|
-63.5
|
RMS power (A-weighted), dB |
-76.3
|
-75.3
|
Peak level, dB FS |
-55.5
|
-56.2
|
DC offset, % |
+0.0
|
-0.0
|
Left
|
Right
|
|
THD, % |
+0.0007
|
+0.0020
|
THD + Noise, % |
+0.1794
|
+0.1388
|
THD + Noise (A-weighted), % |
+0.0353
|
+0.0378
|
Left
|
Right
|
|
IMD + Noise, % |
+0.1109
|
+0.1558
|
IMD + Noise (A-weighted), % |
+0.0436
|
+0.0475
|
Left
|
Right
|
|
Crosstalk at 100 Hz, dB |
-61
|
-59
|
Crosstalk at 1000 Hz, dB |
-79
|
-79
|
Crosstalk at 10000 Hz, dB |
-78
|
-87
|