RightMark Audio Analyzer test report

Musical Fidelity VLPS

S/N 03253VLPS

VLPS


Testing device Musical Fidelity VLPS
Sampling mode 24-bit, 96 kHz
Interface  
Testing chain External loopback (line-out - line-in)
RMAA Version 6.2.5
Calibration signal, Hz 1000
Polarity correct/correct



Summary

RIAA Frequency Accuracy (from 40 Hz to 15 kHz), dB
+0.40, -1.04
Noise level, dB (A)
-67.5
THD, %
0.0017
THD + Noise, dB (A)
-61.4
IMD + Noise, %
0.354
Stereo crosstalk, dB
-68.4
IMD at 10 kHz, %
0.022



RIAA Accuracy & THD

Spectrum graph

  RIAA Frequency Accuracy
Left
Right
From 20 Hz to 20 kHz, dB
-1.47, +0.40
-1.55, +0.38
From 40 Hz to 15 kHz, dB
-0.98, +0.40
-1.04, +0.38



Noise level

Spectrum graph

 
Left
Right
RMS power, dB
-56.7
-54.6
RMS power (A-weighted), dB
-68.2
-66.9
Peak level, dB FS
-45.4
-47.6
DC offset, %
-0.0
-0.0



Dynamic range

Spectrum graph

 
Left
Right
Dynamic range, dB
+57.1
+55.0
Dynamic range (A-weighted), dB
+68.4
+67.0
DC offset, %
-0.00
+0.00



THD + Noise (at -3 dB FS)

Spectrum graph

 
Left
Right
THD, %
+0.0017
+0.0017
THD + Noise, %
+0.2906
+0.3667
THD + Noise (A-weighted), %
+0.0782
+0.0917



Intermodulation distortion

Spectrum graph

 
Left
Right
IMD + Noise, %
+0.3323
+0.3760
IMD + Noise (A-weighted), %
+0.0933
+0.1070



Stereo crosstalk

Spectrum graph

 
Left
Right
Crosstalk at 100 Hz, dB
-53
-54
Crosstalk at 1000 Hz, dB
-66
-69
Crosstalk at 10000 Hz, dB
-74
-74